一、第一步获取安装文件,官网目前搜索也找不到了,这里附件提供之前保存的安装文件
二、使用VMware vSphere Client连接ESXI在配置里启用ssh服务,然后通过ssh客户端工具连接ESXI,安装文件通过sftp上传或者在ESXI上下载都可以,本文文件上传至/tmp目录。
三、安装MegaCli
esxcli software vib install -v /tmp/vmware-esx-MegaCli-8.04.07.vib --no-sig-check
四、MegaCli使用
cd /opt/lsi/MegaCLI/
#查看磁盘状态
./MegaCli -PDList -aAll | grep "Firmware state:"
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
#查看RAID信息
./MegaCli -LDinfo -Lall -aAll
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :Virtual Disk 0
RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3
Size : 836.625 GB
Parity Size : 278.875 GB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 4
Span Depth : 1
Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disk's Default
Encryption Type : None
Is VD Cached: No
五、相关命令
./MegaCli -LDInfo -Lall -aALL 查raid级别
./MegaCli -AdpAllInfo -aALL 查raid卡信息
./MegaCli -PDList -aALL 查看硬盘信息
./MegaCli -AdpBbuCmd -aAll 查看电池信息
./MegaCli -FwTermLog -Dsply -aALL 查看raid卡日志
./MegaCli -adpCount 【显示适配器个数】
./MegaCli -AdpGetTime –aALL 【显示适配器时间】
./MegaCli -AdpAllInfo -aAll 【显示所有适配器信息】
./MegaCli -LDInfo -LALL -aAll 【显示所有逻辑磁盘组信息】
./MegaCli -PDList -aAll 【显示所有的物理信息】
./MegaCli -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’ 【查看充电状态】
./MegaCli -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】
./MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】
./MegaCli -AdpBbuCmd -GetBbuDesignInfo -aALL 【显示BBU设计参数】
./MegaCli -AdpBbuCmd -GetBbuProperties -aALL 【显示当前BBU属性】
./MegaCli -cfgdsply -aALL 【显示Raid卡型号,Raid设置,Disk相关信息】
5.1、磁带状态的变化,从拔盘,到插盘的过程中。
Device |Normal|Damage|Rebuild|Normal
Virtual Drive |Optimal|Degraded|Degraded|Optimal
Physical Drive |Online|Failed –> Unconfigured|Rebuild|Online
5.2、查看磁盘缓存策略
./MegaCli -LDGetProp -Cache -L0 -a0
./MegaCli -LDGetProp -Cache -L1 -a0
./MegaCli -LDGetProp -Cache -LALL -a0
./MegaCli -LDGetProp -Cache -LALL -aALL
./MegaCli -LDGetProp -DskCache -LALL -aALL
5.3、设置磁盘缓存策略
缓存策略解释:
WT (Write through
WB (Write back)
NORA (No read ahead)
RA (Read ahead)
ADRA (Adaptive read ahead)
Cached
Direct
例子:
./MegaCli -LDSetProp WT|WB|NORA|RA|ADRA -L0 -a0
./MegaCli -LDSetProp -Cached|-Direct -L0 -a0
enable / disable disk cache
./MegaCli -LDSetProp -EnDskCache|-DisDskCache -L0 -a0
5.4、创建一个raid5阵列,由物理盘 1,2,3构成,该阵列的热备盘是物理盘4
./MegaCli -CfgLdAdd -r5 [32:1,32:2,32:3] WB Direct -Hsp[32:4] -a0
5.5、创建阵列,不指定热备
./MegaCli -CfgLdAdd -r5 [32:1,32:2,32:3] WB Direct -a0
5.6、删除阵列
./MegaCli -CfgLdDel -L1 -a0
5.7、在线添加磁盘
./MegaCli -LDRecon -Start -r5 -Add -PhysDrv[32:5] -L1 -a0
5.8、阵列创建完后,会有一个初始化同步块的过程,可以看看其进度。
./MegaCli -LDInit -ShowProg -LALL -aALL
或者以动态可视化文字界面显示
./MegaCli -LDInit -ProgDsply -LALL -aALL
5.9、查看阵列后台初始化进度
./MegaCli -LDBI -ShowProg -LALL -aALL
或者以动态可视化文字界面显示
./MegaCli -LDBI -ProgDsply -LALL -aALL
5.10、指定第5块盘作为全局热备
./MegaCli -PDHSP -Set [-EnclAffinity] [-nonRevertible] -PhysDrv[32:5] -a0
5.11、指定为某个阵列的专用热备
./MegaCli -PDHSP -Set [-Dedicated [-Array1]] [-EnclAffinity] [-nonRevertible] -PhysDrv[32:5] -a0
5.12、删除全局热备
./MegaCli -PDHSP -Rmv -PhysDrv[32:5] -a0
5.13、将某块物理盘下线/上线
./MegaCli -PDOffline -PhysDrv [32:5] -a0
./MegaCli -PDOnline -PhysDrv [32:5] -a0
5.14、查看物理磁盘重建进度
./MegaCli -PDRbld -ShowProg -PhysDrv [32:5] -a0
或者以动态可视化文字界面显示
./MegaCli -PDRbld -ProgDsply -PhysDrv [32:5] -a0
5.15、查看Foreign状态的磁盘
./MegaCli -CfgForeign -Scan -a0
5.16、清除Foreign状态
./MegaCli -CfgForeign -Clear -a0
5.17、获取某个盘的详细信息
./MegaCli -pdInfo -PhysDrv[32:1] -a0
5.18、创建raid10
./MegaCli -CfgSpanAdd -r10 -Array0[32:1,32:2] -Array1[32:3,32:4] WB Direct -a0
使用MegaCli在线操作raid还是很方便的,在其他操作系统上也有相应的安装包可以使用,感兴趣的可以自己找台机器试试。
参考文档:
http://de.community.dell.com/techcenter/support-services/w/wiki/909.how-to-install-megacli-on-esxi-5-x
下载文件
二、使用VMware vSphere Client连接ESXI在配置里启用ssh服务,然后通过ssh客户端工具连接ESXI,安装文件通过sftp上传或者在ESXI上下载都可以,本文文件上传至/tmp目录。
三、安装MegaCli
esxcli software vib install -v /tmp/vmware-esx-MegaCli-8.04.07.vib --no-sig-check
四、MegaCli使用
cd /opt/lsi/MegaCLI/
#查看磁盘状态
./MegaCli -PDList -aAll | grep "Firmware state:"
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
#查看RAID信息
./MegaCli -LDinfo -Lall -aAll
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :Virtual Disk 0
RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3
Size : 836.625 GB
Parity Size : 278.875 GB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 4
Span Depth : 1
Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disk's Default
Encryption Type : None
Is VD Cached: No
五、相关命令
./MegaCli -LDInfo -Lall -aALL 查raid级别
./MegaCli -AdpAllInfo -aALL 查raid卡信息
./MegaCli -PDList -aALL 查看硬盘信息
./MegaCli -AdpBbuCmd -aAll 查看电池信息
./MegaCli -FwTermLog -Dsply -aALL 查看raid卡日志
./MegaCli -adpCount 【显示适配器个数】
./MegaCli -AdpGetTime –aALL 【显示适配器时间】
./MegaCli -AdpAllInfo -aAll 【显示所有适配器信息】
./MegaCli -LDInfo -LALL -aAll 【显示所有逻辑磁盘组信息】
./MegaCli -PDList -aAll 【显示所有的物理信息】
./MegaCli -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’ 【查看充电状态】
./MegaCli -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】
./MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】
./MegaCli -AdpBbuCmd -GetBbuDesignInfo -aALL 【显示BBU设计参数】
./MegaCli -AdpBbuCmd -GetBbuProperties -aALL 【显示当前BBU属性】
./MegaCli -cfgdsply -aALL 【显示Raid卡型号,Raid设置,Disk相关信息】
5.1、磁带状态的变化,从拔盘,到插盘的过程中。
Device |Normal|Damage|Rebuild|Normal
Virtual Drive |Optimal|Degraded|Degraded|Optimal
Physical Drive |Online|Failed –> Unconfigured|Rebuild|Online
5.2、查看磁盘缓存策略
./MegaCli -LDGetProp -Cache -L0 -a0
./MegaCli -LDGetProp -Cache -L1 -a0
./MegaCli -LDGetProp -Cache -LALL -a0
./MegaCli -LDGetProp -Cache -LALL -aALL
./MegaCli -LDGetProp -DskCache -LALL -aALL
5.3、设置磁盘缓存策略
缓存策略解释:
WT (Write through
WB (Write back)
NORA (No read ahead)
RA (Read ahead)
ADRA (Adaptive read ahead)
Cached
Direct
例子:
./MegaCli -LDSetProp WT|WB|NORA|RA|ADRA -L0 -a0
./MegaCli -LDSetProp -Cached|-Direct -L0 -a0
enable / disable disk cache
./MegaCli -LDSetProp -EnDskCache|-DisDskCache -L0 -a0
5.4、创建一个raid5阵列,由物理盘 1,2,3构成,该阵列的热备盘是物理盘4
./MegaCli -CfgLdAdd -r5 [32:1,32:2,32:3] WB Direct -Hsp[32:4] -a0
5.5、创建阵列,不指定热备
./MegaCli -CfgLdAdd -r5 [32:1,32:2,32:3] WB Direct -a0
5.6、删除阵列
./MegaCli -CfgLdDel -L1 -a0
5.7、在线添加磁盘
./MegaCli -LDRecon -Start -r5 -Add -PhysDrv[32:5] -L1 -a0
5.8、阵列创建完后,会有一个初始化同步块的过程,可以看看其进度。
./MegaCli -LDInit -ShowProg -LALL -aALL
或者以动态可视化文字界面显示
./MegaCli -LDInit -ProgDsply -LALL -aALL
5.9、查看阵列后台初始化进度
./MegaCli -LDBI -ShowProg -LALL -aALL
或者以动态可视化文字界面显示
./MegaCli -LDBI -ProgDsply -LALL -aALL
5.10、指定第5块盘作为全局热备
./MegaCli -PDHSP -Set [-EnclAffinity] [-nonRevertible] -PhysDrv[32:5] -a0
5.11、指定为某个阵列的专用热备
./MegaCli -PDHSP -Set [-Dedicated [-Array1]] [-EnclAffinity] [-nonRevertible] -PhysDrv[32:5] -a0
5.12、删除全局热备
./MegaCli -PDHSP -Rmv -PhysDrv[32:5] -a0
5.13、将某块物理盘下线/上线
./MegaCli -PDOffline -PhysDrv [32:5] -a0
./MegaCli -PDOnline -PhysDrv [32:5] -a0
5.14、查看物理磁盘重建进度
./MegaCli -PDRbld -ShowProg -PhysDrv [32:5] -a0
或者以动态可视化文字界面显示
./MegaCli -PDRbld -ProgDsply -PhysDrv [32:5] -a0
5.15、查看Foreign状态的磁盘
./MegaCli -CfgForeign -Scan -a0
5.16、清除Foreign状态
./MegaCli -CfgForeign -Clear -a0
5.17、获取某个盘的详细信息
./MegaCli -pdInfo -PhysDrv[32:1] -a0
5.18、创建raid10
./MegaCli -CfgSpanAdd -r10 -Array0[32:1,32:2] -Array1[32:3,32:4] WB Direct -a0
使用MegaCli在线操作raid还是很方便的,在其他操作系统上也有相应的安装包可以使用,感兴趣的可以自己找台机器试试。
参考文档:
http://de.community.dell.com/techcenter/support-services/w/wiki/909.how-to-install-megacli-on-esxi-5-x